Arty – XADC Alarms & References

Facebooktwittergoogle_plusredditpinterestlinkedinmail

One of the most common uses of the XADC is for health monitoring of the FPGA and the wider system to that mind the XADC has a number of useful features which can be used.

  1. Trigger and Reset Threshold Alarm registers for the Internal voltages and temperature parameters
  2. Over Temp Monitoring – Maximum junction operating temperature allowable for the device – Auto shut down is possible.
  3. Maximum and Minimum values – Registers which contain the lowest and highest sampled values for each of the voltages and device temperature.

These three elements make for a very useful health monitoring system, of course the alarms and the over temperature must be correctly configured and enabled first. This can be achieved in one of two ways, either via the XADC wizard within Vivado or via our software application.

1

There are seven possible alarms we can configure on the XADC, however we cannot use all of them on the Artix Silicon as some alarms as dedicated to the Zynq (Alarm 6 Vccddro, Alarm 5 Vccpaux and Alarm 4 Vccpint). There is also an eighth alarm bit which is the logical OR of the seven alarm bits and acts as an overall alarm.

We can see if an alarm has occurred via either the Alarm Status Output Register or configure an interrupt to occur should an alarm condition occur such that it can be immediately dealt with.

2

These trigger and reset values allow us to define values which align with our worst case analysis of supply voltages and junction temperature, ensuring we can protect the system properly.

Each alarm also has an associated output which can be used in the wider system either to indicate via a LED a issue has occurred or to take further action e.g. graceful system degradation.

The over temperature alarm is slightly different in that it can be configured to trigger an automatic shutdown of the device. To set automatic shut down the four LSB’s of the over temperature register must be set high. Doing this means that 10 ms after the trigger level is reached a shut down occurs. This prevents re -configuration of the device until the reset level is reached.

It is intended that the temperature alarm is used to act as a pre-warning that the temperature has exceed what the design has calculated as its maximum. This way the system can take action to prevent the shut down e.g. turning on fans, reducing processing etc.

3

While the maximum and minimum registers provide the system with a simple methodology of quickly and easily checking the worst case values as currently observed by the system during its period of operation. These registers can also be of good use in system commissioning to record supply voltages and temperatures  across worst case environmental conditions for example.

There is also one last issue which must be addressed when using the XADC on the Arty board and that is we need to correctly set up the board to use the internal VRefp. Failure to do this results in a inaccurate conversions.  The Arty board is configured such that you can use either the internal or external reference.

4

 

5

We can ensure the internal reference is used by grounding the XADCVREF input, as such the internal reference will be used. This can be confirmed by reading the flag register which also helpfully contains information on any alarms as well

6

With the XADC configured to correctly monitor the internal signals with suitable alarm levels we can look at how we can use the XADC to receive analogue signals from the real world